Series: BE110
Bellator Engineers manufactures a comprehensive range of Ventilation Channel Closing Device (VChCD) in sizes from 400 mm to 2600 mm Square/Rectangular Shape and Pressure rating up to 1 bar. They are also known as Safety or Emergency Devices. They are used for protecting the compartments against Air Shock waves and Deflagration Waves. These Devices are Bi-Directional and they are designed For Closure against the impact of Air Shock wave and Deflagration Waves. This device ensures that the change in compartment/ Protected Rooms pressure shall not be more than 5 Kpa. Cam mechanism is provided for blade locking during maintenance
Ventilation Channel Closing Device with Adaptor
Our Products
Specifications For Ventilation Channel Closing Device
Size Range :- 400 mm to 2600 mm
Material Of Construction :- ASTM A 240 Type 304L / ASTM A 240 Type 316L / ASTM A 240 Type 321 / As per Client Requirement.
Flowing Media :- Shock Waves
Design Temperature :- -25°C to 825°C
Pressure Ratings :- PN1
End Connection :- Double Flanged (With Adaptor / Without Adaptor)
Face to Face :- API 609 / ASME B16.10 / ISO 5752 / BS EN 558 / Mfg. STD.
Flange Drilling :- IS 6392 / ASME B16.5 / ASME B16.47 / BS EN 1092-1/ Mfg. STD
Testing :- AMCA 511 / ASME AG-1 / ANSI FCI 70-2 / Mfg. STD
Sealing Efficiency :- 100 % to Atmosphere.
Drive Mode :- Shock Wave Impact / Deflagration Wave impact.
Design Codes and Standards :- ASME B16.34 / ASME AG-1 / ERDA 76-21 / ASME SEC VIII; SEC V; SEC IX.